Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1506149.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 07/01/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/07/2021
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 07/07/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/07/2021 | $0.00 | 07/01/2021 | Serious | |
Penalty | Z: Issued | 06/07/2021 | $0.00 | 07/01/2021 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources: On or about December 7, 2020, employees conducting maintenance on machine 4065 were exposed to being caught-in the machine die, in that the electrical, hydraulic, and pneumatic energy sources were not isolated.