Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1476610.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 10/27/2020
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 11/05/2020
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 11/25/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/25/2020 | $0.00 | 11/05/2020 | Serious | |
| Penalty | Z: Issued | 10/27/2020 | $13,494.00 | 11/05/2020 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d): 29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) were not done in sequence as required by 29 CFR 1910.147 (d)(1)-(6): A) Centrex Plastics, LLC, doing business as American Plastics, located at 814 W Lima St, Findlay, OH 45840: On or about May 21, 2020, the employer did not ensure that all the steps outlined in 29 CFR 1910.147(d), required for the control of the hazardous energy sources, were performed. Employees did not de-energize and lockout all hazardous energy sources of the Milacron Maxima Plastic Injection Press # 91 (Product # MPS-1100; Serial # M7001AB010099) prior to conducting activities such as, but not limited to, troubleshooting air poppets in the press. Employees were exposed to struck-by and caught-in-between hazards that could result in serious injuries while performing this task.