Violation Detail
Standard Cited: 19100219 H01 Mechanical power-transmission apparatus.
Inspection Nr: 1470998.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/15/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0111700
Contest Date:
Final Order: 08/27/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/27/2020 | $0.00 | Serious | ||
| Penalty | Z: Issued | 06/15/2020 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s). Location: shop On or about 3/24/2020, employees were exposed to a caught-by hazard when the employer did not ensure the set screws on the Driver, which connects the power transmission shaft to the roll core, were flush or guarded on a Shaffer two wheel roll grinder.