Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1467533.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,481.00
Current Penalty: $0.00
Issuance Date: 05/04/2020
Nr Instances: 3
Nr Exposed: 12
Abatement Date: 05/22/2020
Gravity: 5
Report ID: 0522500
Contest Date: 05/20/2020
Final Order: 09/14/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/14/2020 | $0.00 | 05/22/2020 | Serious | |
Penalty | C: Contested | 06/04/2020 | $8,481.00 | 05/22/2020 | Serious | |
Penalty | Z: Issued | 05/04/2020 | $8,481.00 | 05/22/2020 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. a. On or about March 6, 2020, and at times thereto, employees operating Laminator 4 were exposed to an unguarded protruding shaft end on the Foil Unwind shaft and Paper Unwind shaft. b. On or about March 6, 2020, and at times thereto, employees operating the Johnstown Slitter were exposed to an unguarded protruding shaft end on the bottom roller of the Web Guide section. c. On or about March 6, 2020, and at times thereto, employees operating the Laminator 7 were exposed to an unguarded shaft end on Foil Unwind 1 shaft.