Violation Detail
Standard Cited: 19100219 C04 II Mechanical power-transmission apparatus.
Inspection Nr: 1465623.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/19/2020
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 09/18/2020
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 09/24/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/24/2020 | $0.00 | 09/18/2020 | Serious | |
Penalty | Z: Issued | 08/19/2020 | $0.00 | 09/18/2020 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered. (a) Plant 2 S9 Slitter Conveyor - On or about February 26, 2020 the employer did not ensure that a rotating shaft with keyway at the of a transfer conveyor was guarded, exposing employees to a caught-in hazard.