Violation Detail
Standard Cited: 19260502 D17 Fall protection systems criteria and practices.
Inspection Nr: 1424506.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/23/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/19/2019
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 12/20/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 10/23/2019 | $0.00 | 11/19/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head. On or about August 16, 2019, at Lot 73, 8705 Mica Creek, Ball Ground, Georgia: One employee performing roofing work was exposed to a fall hazard of approximately 10.3-feet and greater when he did not use a full body harness and tied off directly to the webbing of a rock climbing harness in the front at waist level.
Translate