Violation Detail
Standard Cited: 19100147 C06 I C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1417490.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/09/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/28/2020
Gravity: 10
Report ID: 0112600
Contest Date:
Final Order: 01/07/2020
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/07/2020 | $0.00 | 01/28/2020 | Serious | |
Penalty | Z: Issued | 12/09/2019 | $0.00 | 01/28/2020 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. (a) Site: On the production floor, at Van Dorn 350 Ton Press #1019, in the facility at 100 Simplex Drive, Westminster, MA 01453: On 7/23/2019 where lockout was used for energy control a LOTO inspector did not review the inspection results from the Van Dorn 350 Ton Press #1019 with each authorized employee before that employee performed maintenance on the machine.