Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1410032.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $8,000.00
Issuance Date: 11/14/2019
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 12/11/2019
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 12/10/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/10/2019 | $8,000.00 | 12/11/2019 | Serious | |
Penalty | Z: Issued | 11/14/2019 | $0.00 | 12/11/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically outline specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about June 12, 2019, employees perform maintenance and service on various equipment. Employees were exposed to struck by, caught in and amputation hazards in that: a) Extrusion line 1-8, Thermal Energy 200F- The procedures do not indicate how much time employees need to wait until the machine cools off, it also does not indicated the PPE to be used. b) Extrusion line 1-8, Kinetic Energy 1800 RPM- The Procedures does not indicate how long to wait for equipment to come to stop and addition it does not indicate the location and how to use the block or chain to stop equipment from moving.