Violation Detail
Standard Cited: 19261435 F05
Inspection Nr: 1408500.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/06/2019
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 01/03/2020
Gravity: 10
Report ID: 0626300
Contest Date: 12/23/2019
Final Order: 08/11/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/11/2021 | $0.00 | 01/03/2020 | Serious | |
Penalty | C: Contested | 12/26/2019 | $0.00 | 01/03/2020 | Serious | |
Penalty | Z: Issued | 12/06/2019 | $0.00 | 01/03/2020 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.1435(f)(5): Annual. In addition to the items that must be inspected under 1926.1412(f), all turntable and tower bolts must be inspected for proper condition and torque. On or about June 8, 2019, and times prior to an annual inspection was not completed for the Peiner model SK415-20 serial G11216005 tower crane.