Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1399868.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,304.00
Current Penalty: $0.00
Issuance Date: 08/12/2019
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 10/25/2019
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 08/22/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection | 
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/22/2019 | $0.00 | 10/25/2019 | Serious | |
| Penalty | Z: Issued | 08/12/2019 | $5,304.00 | 09/04/2019 | Serious | 
Text For Citation: 01 Item/Group: 002B Hazard:
29CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection. a) On or about 05/08/2019, throughout establishment including the reamer machine, the periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection.
 Translate
Translate