Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1384915.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/20/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/07/2019
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 08/20/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/20/2019 | $0.00 | 08/07/2019 | Serious | |
Penalty | Z: Issued | 06/20/2019 | $0.00 | 08/07/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Co-Mail Department - On March 13, 2019, the employer failed to develop procedures which outlined the scope, purpose, authorization, rules, and techniques for controlling hazardous energy while performing service and maintenance on the Line 3 Goss Loudon Stacker. An employee was thereby exposed to the unexpected energization and/or startup of the equipment.