Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1383721.015
Citation: 01002B
Citation Type: Other
Abatement Date: 09/24/2019 5
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/28/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date: 09/17/2019
Final Order: 02/13/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/13/2020 | $0.00 | 09/24/2019 | Other | |
Penalty | C: Contested | 09/25/2019 | $0.00 | 09/24/2019 | Serious | |
Penalty | Z: Issued | 08/28/2019 | $0.00 | 09/24/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. (a) On or about March 12, 2019, the compressor had a horizontal belt that was not adequately guarded, thereby exposing the employee to a caught-in hazard.