Violation Detail
Standard Cited: 19100147 D06 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1377997.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,503.00
Current Penalty: $0.00
Issuance Date: 07/30/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/11/2021
Gravity: 5
Report ID: 0728500
Contest Date: 08/19/2019
Final Order: 05/11/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/11/2020 | $0.00 | 01/11/2021 | Serious | |
| Penalty | C: Contested | 08/21/2019 | $12,503.00 | 09/16/2019 | Serious | |
| Penalty | Z: Issued | 07/30/2019 | $12,503.00 | 09/16/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished. The employer is failing to protect employees from caught-in, struck-by, and electric shock hazards associated with servicing and maintaining equipment with hazardous stored energy. This was most recently documented on March 13, 2019 at a worksite located at 1078 S Jefferson Ave, Lebanon, Missouri. The employer had employees servicing the Head Sander Station 4 without verifying through attempted re-start that the equipment was de-energized during the isolation procedure.