Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1364411.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/11/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 04/02/2019
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 04/10/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/10/2019 | $0.00 | 04/02/2019 | Serious | |
| Penalty | Z: Issued | 03/11/2019 | $0.00 | 04/02/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) NP4-3 Needle Press - On or about November 30, 2018 the employer had not conducted the periodic inspection of their energy control procedures to ensure they adequately identified all sources of potential hazards to employees, exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing task including but not limited to servicing, maintenance and jam clearing.