Powered by GoogleTranslate

Violation Detail

Standard Cited: 19260502 F01 III Fall protection systems criteria and practices.

Inspection Nr: 1334598.015

Citation: 01002B

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $0.00

Current Penalty: $0.00

Issuance Date: 10/04/2018

Nr Instances: 1

Nr Exposed: 6

Abatement Date: 10/31/2018

Gravity: 5

Report ID: 0419700

Contest Date:

Final Order: 11/29/2018

Related Event Code (REC): R

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty Z: Issued 10/04/2018 $0.00 10/31/2018 Serious  

Text For Citation: 01 Item/Group: 002B Hazard:

29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: a) On or about July 24, 2018, the employer failed to ensure that on the flat roof of the building locate at 1260 Palm Coast Pkwy SW in Palm Coast Florida where the employees were conducting roofing activities the point of access used for disposing of materials was connected to the work area by a path formed by two warning lines. Employees disposing materials by tossing the materials over the warning lines from the working area were exposed to a fall of more than six (6) feet.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close