Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1321978.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 09/24/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/28/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 09/26/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/26/2018 | $0.00 | 09/24/2018 | Serious | |
Penalty | Z: Issued | 08/28/2018 | $0.00 | 09/24/2018 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Green J-Bar Sorter: On June 6, 2018 and at times prior thereto the energy for the descrambler, descrambler in-feed chain and photo eye were not shut off and the energy properly isolated prior to an employee attempting to perform unscheduled maintenance on the J-bar sorter. Note) Certification and documentation of corrective actions are required for this item.