Violation Detail
Standard Cited: 19101025 E01 I Lead.
Inspection Nr: 1310366.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 02/22/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/05/2018
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): C
Gravity: 10
Report ID: 0728900
Contest Date:
Final Order: 11/01/2018
Emphasis:
Substance: 1591
Substance: C141
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/01/2018 | $0.00 | 02/22/2019 | Serious | |
Penalty | Z: Issued | 10/05/2018 | $0.00 | 02/22/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.1025(e)(1)(i): For any employees exposed to lead above the permissible exposure limit for more than 30 days per year the employer did not implement engineering and work practice controls (including administrative controls) were not implemented to reduce and maintain employee exposure to lead in the Reclaim / Deblocking area. The employer is failing to implement effective engineering and work practice controls for an employee exposed to lead above the permissible exposure level for more than 30 days per year. On or about August 10, 2010, an employee engaged in melting a lead/cadmium/bismuth alloy was exposed to airborne lead approximately 1.46 times the permissible exposure limit, and engineering controls and/or work practice controls had not been implemented.