Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1303256.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/06/2018
Nr Instances: 2
Nr Exposed: 4
Abatement Date: 11/11/2018
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 06/29/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | $0.00 | 11/11/2018 | Serious | ||
Penalty | I: Informal Settlement | 06/29/2018 | $0.00 | 08/13/2018 | Serious | |
Penalty | Z: Issued | 06/06/2018 | $0.00 | 07/11/2018 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. On or about March 21, 2018, employees were exposed to machine hazards associated with moving parts and crushing hazards while troubleshooting the fiber optic laser machine located in the production area. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. b. On or about April 5, 2018, employees were exposed to machine hazards associated with high pressure heated water while cleaning the high pressure wash located in the production area. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.