Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1254389.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/22/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/10/2017
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 09/07/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/07/2017 | $0.00 | 10/10/2017 | Serious | |
| Penalty | Z: Issued | 08/22/2017 | $0.00 | 10/10/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(d)(1): Pulleys, any parts of which were seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section: At 1500 Ardagh Group Drive, Pevely, MO 63070, specifically inside of the Maintenance Department, the belt and pulley belonging to the Bridgeport Milling Machine, m/n 65088, s/n J-68423, were unguarded. This violation was observed on 08/15/17.