Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1253549.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/19/2018
Nr Instances: 1
Nr Exposed: 11
Abatement Date: 02/05/2018
Gravity: 5
Report ID: 0625500
Contest Date: 02/12/2018
Final Order: 11/02/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/02/2018 | $0.00 | 02/05/2018 | Serious | |
Penalty | C: Contested | 02/23/2018 | $0.00 | 02/05/2018 | Serious | |
Penalty | Z: Issued | 01/19/2018 | $0.00 | 02/05/2018 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): Krones Bottle Filler: On or about August 8, 2017, and at times prior thereto, employees were exposed to caught-in hazards, when energy isolation devices were not located and operated to isolate all energy sources while employees performed maintenance tasks including, but not limited to, replacing valves.