Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1223393.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/25/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/31/2017
Gravity: 5
Report ID: 0521700
Contest Date:
Final Order: 08/09/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/09/2017 | $0.00 | 07/31/2017 | Serious | |
Penalty | Z: Issued | 07/25/2017 | $0.00 | 07/31/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a. On or about April 6, 2017, in the coil room, the guard that covered the belt and pulley on the Dayton Speedaire air compressor was not installed, thereby exposing employees to the hazards associated with moving machine parts.