Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1181334.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 04/19/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/24/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 04/18/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/18/2017 | $0.00 | 04/19/2017 | Serious | |
Penalty | Z: Issued | 03/24/2017 | $0.00 | 04/19/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) The employer did not conduct a periodic inspection of the energy control (lockout/tagout) procedure(s) for equipment, including but not limited to Converting Machines, Wizard Machines, and other equipment in the Converting Room.