Violation Detail
Standard Cited: 19100335 A02 I Safeguards for personnel protection.
Inspection Nr: 1179464.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/16/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/17/2017
Gravity: 10
Report ID: 0636900
Contest Date:
Final Order: 03/02/2017
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/02/2017 | $0.00 | 03/17/2017 | Serious | |
| Penalty | Z: Issued | 02/16/2017 | $0.00 | 03/17/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: At the jobsite, employees trimming tree branches with a non-insulated 20ft. Stihl aluminum pole saw did not keep the required clearance distances from overhead energized power lines, exposing employees to the hazard of electric shock, severe burns and electrocution.