Violation Detail
Standard Cited: 19101025 H02 I Lead.
This violation item has been deleted.
Inspection Nr: 1172081.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 02/10/2017
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/31/2017
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0936400
Contest Date:
Final Order: 03/01/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/01/2017 | $0.00 | 02/10/2017 | Serious | |
Penalty | Z: Issued | 01/31/2017 | $0.00 | 02/10/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.1025(h)(2)(i): Floors and other surfaces where lead accumulates were cleaned by the use of compressed air. a) ASARCO Hayden Smelter, Converter Baghouse area: Compressed air was used to remove lead accumulations in the Converter Baghouse Hoppers and surrounding area. Employees were exposed to airborne lead accumulates.