Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1161984.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/27/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/26/2017
Gravity: 10
Report ID: 0521100
Contest Date: 01/18/2017
Final Order: 01/02/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/02/2018 | $0.00 | 01/26/2017 | Serious | |
Penalty | C: Contested | 01/23/2017 | $0.00 | 01/26/2017 | Serious | |
Penalty | Z: Issued | 12/27/2016 | $0.00 | 01/26/2017 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: On or about June 29, 2016, an employee that suffered an amputation during setup activities was not trained on lockout tagout to safely perform servicing and maintenance activities on the Michael Weinig Hydromat 22AL molding machine on Line #12.