Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1136593.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/14/2016
Nr Instances: 3
Nr Exposed: 1
Abatement Date: 05/03/2016
Gravity: 10
Report ID: 0830300
Contest Date:
Final Order: 05/02/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/02/2016 | $0.00 | 05/03/2016 | Serious | |
| Penalty | Z: Issued | 04/14/2016 | $0.00 | 05/03/2016 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards of machines were not designed and constructed to prevent an employee from injury by having a part of their body in the danger zone during operating cycles: (a) On or about March 30, 2016 and at time prior to that date, for the employees exposed to amputation hazards while operating a Cincinnati 75 ton press brake in the welding and fabrication room at 104 First Street Southwest, Cooperstown, North Dakota. (b) On or about March 30, 2016 and at time prior to that date, for the employees exposed to amputation hazards while operating a Steelweld press brake, Model No. H3 ½ -12, Serial No. M-2350 in the welding and fabrication room at 104 First Street Southwest, Cooperstown, North Dakota. (c) On or about March 30, 2016 and at time prior to that date, for the employees exposed to amputation hazards while operating a Steelweld press brake, Model No. AI-4-16-22, Serial No. MO-9770 in the fabrication room at 104 First Street Southwest, Cooperstown, North Dakota.
Translate