Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1097877.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/11/2016
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 04/01/2016
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 04/04/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/04/2016 | $0.00 | 04/01/2016 | Serious | |
Penalty | Z: Issued | 03/11/2016 | $0.00 | 04/01/2016 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): During the period between September 21, 2015 and February 8, 2016: The energized sweep auger drive belts were less than seven feet above the floor, and were not guarded when employees entered the grain bin(s).