Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1066299.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/18/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/08/2015
Gravity: 5
Report ID: 0317300
Contest Date:
Final Order: 12/11/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/11/2015 | $0.00 | 12/08/2015 | Serious | |
Penalty | Z: Issued | 11/18/2015 | $0.00 | 12/08/2015 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) 24483 Sussex Highway, Seaford, DE, Ice bagging machine, Bagging Area, Back of Ice machine 1- On or about May 28, 2015 the employer failed to guard the vertical belt in the ice machine, exposing employees to potential amputation hazards. The employees walk approximately 2 feet from the unguarded belt.