Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1065001.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,500.00
Current Penalty: $0.00
Issuance Date: 11/05/2015
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 08/01/2016
Gravity: 5
Report ID: 0213600
Contest Date: 11/25/2015
Final Order: 03/14/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/14/2016 | $0.00 | 08/01/2016 | Serious | |
Penalty | C: Contested | 11/30/2015 | $5,500.00 | 12/06/2015 | Serious | |
Penalty | Z: Issued | 11/05/2015 | $5,500.00 | 12/06/2015 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 05/28/15 throughout the production areas; employer failed to protect employees involved in service and maintenance activities from amputation and caught between hazards, when periodic inspections of the energy control procedures of machines, such as but not limited to Muffler Hanger Winder, Muffler Hanger Cutter, Muffler Hanger Machine (vertical), were not conducted to verify accuracy of the procedures and compliance by Authorized employees. ABATEMENT CERTIFICATION REQUIRED