Violation Detail
Standard Cited: 19260452 W05 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1003442.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,300.00
Current Penalty: $0.00
Issuance Date: 04/14/2015
Nr Instances: 1
Nr Exposed: 17
Abatement Date:
Gravity: 10
Report ID: 0936300
Contest Date:
Final Order: 05/07/2015
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/07/2015 | $0.00 | Serious | ||
| Penalty | Z: Issued | 04/14/2015 | $6,300.00 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.452(w)(5): Scaffolds shall be stabilized to prevent tipping during movement: Dusit Thani Hotel Jobsite, Sixth Floor, Banquet Room 1 and 2: Pacific Rim Land Development permitted a four tier fabricated frame orange mobile scaffold to be moved by employees; the mobile scaffold was not stabilized with outriggers or similar stabilizing devices. On October 18, 2014, the mobile scaffold toppled over fatally injuring a plumber. The scaffold was hazardous in that the scaffold frame legs were not designed with holes to accept mobile scaffold wheel stem pins to prevent the wheels from coming out of the frame legs; and the height to base ratio of the mobile scaffold was greater than 4 to 1. When the orange scaffold toppled it was measured to be 16 feet, 7.5 inches tall and 4 feet wide.