Violation Detail
Standard Cited: 19100134 D01 I Respiratory Protection.
Inspection Nr: 977569.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $2,800.00
Current Penalty: $980.00
Issuance Date: 11/17/2014
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 01/06/2015
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 12/04/2014
Related Event Code (REC):
Emphasis:
Substance: 0260
Substance: 1591
Substance: C141
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/04/2014 | $980.00 | 01/06/2015 | Serious | |
| Penalty | Z: Issued | 11/17/2014 | $2,800.00 | 01/06/2015 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
Construction Reference: 1926.103 NOTE: The requirements applicable to construction work under this section are identical to those set forth at � 1910.134 of this chapter. 29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability: The employer did not select and provide an appropriate respirator based on the respiratory hazard(s) to which the workers were exposed while manually scraping and power sanding old paint containing up to 23.08% lead, 0.0015 % arsenic and 0.0059% cadmium. a) Employees were provided and used 3M Model 8511 negative pressure filtering facepiece N-95 respirators that the manufacturer did not approve for protection against lead, arsenic and cadmium. b) Employees were provided and used 3M Series 6000 half mask respirators equipped with 3M model 6001 Organic Vapor cartridges with a P-95 pre-selector filter. Due to filter cartridge selection (i.e. not HEPA) the respirator did not adequately protect workers against airborne particulate matter.
Translate