Violation Detail
Standard Cited: 19100179 K01 II Overhead and gantry cranes.
This violation item has been deleted.
Inspection Nr: 976253.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 06/04/2014
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/12/2014
Gravity: 10
Report ID: 0420100
Contest Date:
Final Order: 06/30/2014
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/30/2014 | $0.00 | 06/12/2014 | Serious | |
| Penalty | Z: Issued | 06/04/2014 | $7,000.00 | 06/12/2014 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.179(k)(1)(ii): The trip setting of hoist limit switches was not determined by tests with an empty hook traveling in increasing speeds up to the maximum speed: (a) Unit 3 Turbine Housing - On or about 5/7/14, employees were exposed to struck-by and crushing hazards when the limit switch was not tested to ensure proper working order. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).