Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 957548.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 06/11/2014 2
Initial Penalty: $4,250.00
Current Penalty: $2,125.00
Issuance Date: 05/28/2014
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 06/20/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/20/2014 | $2,125.00 | 06/11/2014 | Serious | |
Penalty | Z: Issued | 05/28/2014 | $4,250.00 | 06/11/2014 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) CHS, Steel blue bin shovel rig operations; The shovel rig belt and pulley compressor drive were not fully guarded.