Violation Detail
Standard Cited: 19260451 C02 General requirements.
Inspection Nr: 895394.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 06/27/2013 5
Initial Penalty: $2,400.00
Current Penalty: $2,400.00
Issuance Date: 06/17/2013
Nr Instances: 7
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0627500
Contest Date:
Final Order: 07/11/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 06/17/2013 | $2,400.00 | 06/27/2013 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation. On or about March 13, 2013, a frame scaffold platform with a height of approximately 12 feet from the ground was released for use without legs bearing on base plates and mud sills or other adequate firm foundation. These condition exposed employees to fall and struck-by hazards due to unstable walking working platforms.