Violation Detail
Standard Cited: 19100263 L09 III B Bakery equipment.
Inspection Nr: 1741672.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $14,000.00
Issuance Date: 06/27/2024
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 10/01/2024
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 07/23/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/23/2024 | $14,000.00 | 10/01/2024 | Serious | |
Penalty | Z: Issued | 06/27/2024 | $16,131.00 | 08/14/2024 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.263(l)(9)(iii)(b): Ovens with multiple burners shall be equipped with individual atmospheric pilot lights where there is sufficient secondary air in the baking chamber and where gas is available; or else each burner shall be equipped with an electric spark-type ignition device. a) On or about April 15, 2024, maintenance employees lighting the burners on the Baker Perkins direct gas fired oven (oven #8) in the Roll Line area were exposed electrical shock hazards of two times five thousand volts (2 x 5000 V) at twenty-two milliamperes (22mA); the employer did not ensure all electric spark-type ignition devices were properly maintained and kept in working order requiring employees to manually light the burners.