Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1731438.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,687.00
Current Penalty: $3,687.00
Issuance Date: 07/01/2024
Nr Instances: 2
Nr Exposed: 16
Abatement Date:
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 07/30/2024
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 07/01/2024 | $3,687.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.179(j)(2): Overhead cranes were not inspected for defects on a daily basis for items including but not limited to; all functional operating mechanisms for maladjustment interfering with proper operation, deterioration or leakage of air or hydraulic systems, hooks, hoist chains, all functional operating mechanisms for excessive wear of components, rope reeving for noncompliance with manufacturer's recommendations: a) West Bay, Assembly Crane - Frequent inspections were not conducted on a 10-Ton D.R. Cordell floor operated overhead bridge crane and associated hook, on or about February 29, 2024. b) East Bay, Machine Shop Crane - Frequent inspections were not conducted on a 5-Ton Konecranes floor operated overhead bridge crane and associated hook, on or about February 29, 2024. No abatement�certification or�documentation required.
Translate