Violation Detail
Standard Cited: 19100095 D01 Occupational noise exposure.
Inspection Nr: 1725673.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,452.00
Current Penalty: $5,000.00
Issuance Date: 06/03/2024
Nr Instances: 3
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0213900
Contest Date: 06/26/2024
Final Order: 10/28/2024
Related Event Code (REC): R
Emphasis:
Substance: 8110
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 10/28/2024 | $5,000.00 | Serious | ||
Penalty | C: Contested | 06/26/2024 | $6,452.00 | Serious | ||
Penalty | Z: Issued | 06/03/2024 | $6,452.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.95(d)(1):When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: The employer did not conduct noise monitoring for assemblers and disassemblers exposed to continuous noise levels in excess of the allowable 8-hour time weighted average sound level. a)Pallet assembly area: A pallet assembler's dosimeter reading was 196.2 % of the permissible exposure limit (90dBa) and was equivalent to approximately 94.9 dBa, The sampling was performed for 393 minutes during one shift on 3/21/24 Zero exposure was assumed for the un-sampled period of time. b)Pallet disassembly area: A pallet dismantler's dosimeter reading was 723.4% of the permissible exposure limit (90dBa) and was equivalent to approximately 104.3 dBa. The sampling was performed for 396 minutes during one shift on 3/21/24 Zero exposure was assumed for the un-sampled period of time. c) Pallet assembly area: A pallet assemblers dosimeter reading was 76.7% of the action level (85 dBa) and was equivalent to approximately 88.1 dBa. The sampling was performed for 119 minutes during one shift on 3/21/24 exposure was assumed zero for the un-sampled period of time. The dosimeter was not turned on for the start of the shift, the dosimeter was turned on after employees lunch break.