Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1711402.015
Citation: 01002A
Citation Type: Serious
Abatement Status:
Initial Penalty: $16,131.00
Current Penalty: $0.00
Issuance Date: 05/09/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/05/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 06/06/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/06/2024 | $0.00 | 06/05/2024 | Serious | |
Penalty | Z: Issued | 05/09/2024 | $16,131.00 | 06/05/2024 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: On or about November 12, 2023, in Plant #3, employees performed servicing and maintenance activities on equipment such as, but not limited to, the Thiele Bag Placer, Serial #7138A110. All energy sources including, but not limited to pneumatic energy, were not isolated.