Violation Detail
Standard Cited: 19100106 D04 I Flammable liquids.
Inspection Nr: 1709524.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,067.00
Current Penalty: $4,700.00
Issuance Date: 05/08/2024
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 01/02/2025
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 05/28/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 08/08/2024 | $4,700.00 | 01/02/2025 | Serious | |
Penalty | I: Informal Settlement | 05/28/2024 | $4,700.00 | 01/02/2025 | Serious | |
Penalty | Z: Issued | 05/08/2024 | $8,067.00 | 06/26/2024 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.106(d)(4)(i): "Construction." Inside storage rooms were not constructed to meet the required fire-resistive rating for their use. Such construction did not comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system was not designed and installed in an acceptable manner. Openings to other rooms or buildings were not provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area was not at least 4 inches below the surrounding floor. Openings were not provided with approved self-closing fire doors. The room was not liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which drains to a safe location. Where other portions of the building or other properties are exposed, windows were not protected as set forth in the Standard for Fire Doors and Windows, NFPA No. 80-1968, which is incorporated by reference as specified in Sec. 1910.6, for Class E or F openings. Wood at least 1 inch nominal thickness may be used for shelving, racks, dunnage, scuffboards, floor overlay, and similar installations. On or about April 19, 2024, and at times prior, the following rooms used to store 55 gallon drums of flammable liquids, were open to other rooms with no approved self-closing fire doors, no raised sills or ramps at least 4 inches in height, or the floor in the storage area was not at least 4 inches below the surrounding floor, or did not have an open-grated trench inside of the room which drained to a safe location, and exposed employees to fire hazards: a) Production room b) Raw Materials room