Standard Cited: 19100147 C06 I C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1699180.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $16,131.00
Current Penalty: $8,065.50
Issuance Date: 02/06/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/28/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/28/2024 | $8,065.50 | Serious | ||
Penalty | Z: Issued | 02/06/2024 | $16,131.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(6) Periodic inspection. (i)(C): Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. a) On or about September 20, 2023 in the laundry service department, the employer's inspector did not perform a review of the lockout procedure for the Chicago XXL Folder with each authorized employee during the periodic inspection to occur at least annually, and the lockout procedure had not been updated after the installation of the Siemens electrical enclosure with an exterior disconnect switch.