Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1685324.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,938.00
Current Penalty: $6,562.80
Issuance Date: 01/12/2024
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 02/20/2024
Gravity: 10
Report ID: 0626600
Contest Date:
Final Order: 02/27/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/27/2024 | $6,562.80 | 02/20/2024 | Serious | |
Penalty | Z: Issued | 01/12/2024 | $10,938.00 | 02/20/2024 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about July 22, 2023 and times prior to, at a commercial jobsite located at 7115 Clinton Drive, Houston, TX 77020, on blending line #10, ribbon auger blender, the employer's energy control procedures did not clearly and specifically outline the steps for blocking and securing the ribbon blender to control hazardous energy.