Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1606355.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,164.00
Current Penalty: $3,698.40
Issuance Date: 12/08/2022
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 01/09/2023
Gravity: 5
Report ID: 0523900
Contest Date: 01/06/2023
Final Order: 08/24/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 08/24/2023 | $3,698.40 | 01/09/2023 | Serious | |
| Penalty | C: Contested | 01/09/2023 | $6,164.00 | 01/09/2023 | Serious | |
| Penalty | Z: Issued | 12/08/2022 | $6,164.00 | 01/09/2023 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Iron Horse CNC router; Energy isolation procedures were not utilized while employees performed servicing activities of changing tooling and clearing scraps from router tables.
Translate