Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1595720.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $14,502.00
Issuance Date: 09/06/2022
Nr Instances: 5
Nr Exposed: 450
Abatement Date: 09/30/2022
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 09/27/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/27/2022 | $14,502.00 | 09/30/2022 | Serious | |
Penalty | Z: Issued | 09/06/2022 | $14,502.00 | 09/30/2022 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii)(C):Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: This violation occurred on or about May 13, 2022, where the employer did not ensure the energy control of the lockout/tagout procedures were followed for the Mercury machine. Employees were exposed to an amputation hazard. (a) Mercury 1 machine, serial number: 20210601 (b) Mercury 2 machine, serial number: 20210602 (c) Mercury 3 machine, serial number: 20201201 (d) Mercury 4 machine, serial number: 20210701 (e) Mercury 5 machine, serial number: 20210702