Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1593815.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $10,151.40
Issuance Date: 09/23/2022
Nr Instances: 37
Nr Exposed: 2
Abatement Date: 11/14/2022
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 10/17/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/17/2022 | $10,151.40 | 11/14/2022 | Serious | |
Penalty | Z: Issued | 09/23/2022 | $14,502.00 | 11/10/2022 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Workplace located at 2700 W. 16th St., Sedalia, Missouri- Hallway between Lehr 5 and Lehr 6- Fans 28 & 29 and similar fans were not fully guarded on the back side of the pulley in which employees were required to work above the improperly guarded pulleys in order to ignite pilot lights.