Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1568687.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,052.00
Current Penalty: $9,136.40
Issuance Date: 02/28/2022
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 03/24/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/24/2022 | $9,136.40 | Serious | ||
| Penalty | Z: Issued | 02/28/2022 | $13,052.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 5, 2021, the employer had not ensured that procedures were documented and utilized for the control of potentially hazardous energy including but not limited to electrical as well as steam/wax pressure and heat, while removing hoses in the tank 42 area.