Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1533958.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,653.00
Current Penalty: $13,653.00
Issuance Date: 09/23/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 10/20/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/23/2021 | $13,653.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage: On or about May 22, 2021, the authorized employee performing a belt change on the Riverside saw dust conveyor did not utilize the normal shut down procedures for the equipment. The employee turned off the electrical disconnect which permitted the equipment to restart immediately when the disconnect was turned back on.