Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100254 C03 I Arc welding and cutting.

Inspection Nr: 1525767.015

Citation: 01002A

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $13,653.00

Current Penalty: $9,557.00

Issuance Date: 07/16/2021

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 08/11/2021

Gravity: 10

Report ID: 0522300

Contest Date:

Final Order: 08/12/2021

Related Event Code (REC): A

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 08/12/2021 $9,557.00 08/11/2021 Serious  
Penalty Z: Issued 07/16/2021 $13,653.00 08/11/2021 Serious  

Text For Citation: 01 Item/Group: 002A Hazard:

29 CFR 1910.254(c)(3)(i):A disconnecting switch or controller shall be provided at or near each welding machine which is not equipped with such a switch or controller mounted as an integral part of the machine. The switch shall be in accordance with Subpart S of this part. Overcurrent protection shall be provided as specified in Subpart S of this part. A disconnect switch with overload protection or equivalent disconnect and protection means, permitted by Subpart S of this part, shall be provided for each outlet intended for connection to a portable welding machine. On or about April 12, 2021, the employer did not ensure an outlet intended for the connection of a 30 amp, 480 volt Miller, Millermatic 350P portable welding machine was provided with overcurrent protection as specified in 1910, Subpart S. The overcurrent protection devices being utilized were 150 amp fuses, which were not sufficient protect the 30 amp branch circuit and 30 amp receptacle outlet intended to connect the welding machine.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.