Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1513451.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,513.00
Current Penalty: $5,000.00
Issuance Date: 08/03/2021
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 08/27/2021
Gravity: 10
Report ID: 0214500
Contest Date: 11/30/2021
Final Order: 10/20/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 10/20/2022 | $5,000.00 | 08/27/2021 | Serious | |
Penalty | C: Contested | 12/02/2021 | $10,513.00 | 08/27/2021 | Serious | |
Penalty | Z: Issued | 08/03/2021 | $10,513.00 | 08/27/2021 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Warehouse L3 Room: The employer did not establish an energy control program consisting of procedures or employee training for unjamming a CVC Capper Machine which resulted in an accident, on or about 2/4/21.