Violation Detail
Standard Cited: 19180022 B Gangways.
Inspection Nr: 1499604.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $13,653.00
Issuance Date: 03/08/2021
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 04/01/2021
Gravity: 10
Report ID: 0418400
Contest Date:
Final Order: 04/12/2021
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/12/2021 | $13,653.00 | 04/01/2021 | Serious | |
Penalty | Z: Issued | 03/08/2021 | $13,653.00 | 04/01/2021 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1918.22(b): Each side of the gangway, and the turntable if used, did not have a hand rail with a minimum height of 33 inches (0.84 m)(measured perpendicularly from rail to walking surface at the stanchion) and a midrail. A) Garden City Terminal Vessel Maersk Tukang, on or about 10/27/20, and or times prior to, a section of the gangway on the shore side near the bottom did not have a handrail in place, thereby exposing employees to a drowning hazard. Alternatively: When the presence of such hazard exists, as created by the absence of a guardrail and where the gangway is not situated over the dock, the employer shall also provide a net or other suitable protection.