Powered by GoogleTranslate

Violation Detail

Standard Cited: 19260451 B01 I General requirements.

Inspection Nr: 1479381.015

Citation: 01002A

Citation Type: Serious

Abatement Status: Corrected During Inspection

Initial Penalty: $4,048.00

Current Penalty: $2,428.80

Issuance Date: 06/23/2020

Nr Instances: 1

Nr Exposed: 3

Abatement Date:

Gravity: 10

Report ID: 0418800

Contest Date:

Final Order: 07/23/2020

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 07/23/2020 $2,428.80   Serious  
Penalty Z: Issued 06/23/2020 $4,048.00   Serious  

Text For Citation: 01 Item/Group: 002A Hazard:

29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: On or about 6/11/2010, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from tubular welded frame scaffolds that were not fully planked.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close